August 6, 2025
BiVACOR's Total Artificial Heart Accepted into FDA's Total Product Life Cycle (TAP) Program
BiVACOR, a clinical-stage medical device company developing the world's first titanium Total Artificial Heart (TAH), today announced that its Total Artificial Heart (TAH) has been accepted into the U.S. Food and Drug Administration's (FDA) prestigious Total Product Life Cycle Advisory Program, also known as the TAP program. This milestone deeps the strategic partnership with the FDA following the Break Through Device Designation
May 30, 2025
BiVACOR's Total Artificial Heart Receives FDA Breakthrough Device Designation
BiVACOR, a clinical-stage medical device company developing the world's first titanium Total Artificial Heart (TAH), today announced that its device has received Breakthrough Device Designation from the U.S. Food and Drug Administration (FDA).
March 12, 2025
BiVACOR's Total Artificial Heart Successfully Implanted in First Patient in Australia; TAH in Place Over 100 Days
BiVACOR, a clinical-stage medical device company, announced today the first successful implantation of its Total Artificial Heart (TAH) in Australia. The implant occurred at St.Vincent's Hospital Sydney on November 22, 2024.
December 18, 2024
BiVACOR's Total Artificial Heart Successfully Implanted in Five Patients as Part of FDA Early Feasibility Study; FDA Greenlights Expansion of the EFS
As part of a five-patient FDA Early Feasibility Study, BiVACOR's TAH successfully bridges all five patients to a donor heart transplant. Data supports the expansion of the Early Feasibility Study to an additional 15 patients.
July 26, 2024
The Texas Heart Institute Provides Patient Update on BiVACOR's Total Artificial Heart
The Texas Heart Institute (THI), a globally renowned cardiovascular health center, and BiVACOR, a leading clinical-stage medical device company, are pleased to provide an update on the condition of the first patient to receive BiVACOR's Total Artificial Heart (TAH) implant on July 9, as part of the U.S. Food and Drug Administration (FDA) Early Feasibility Study (EFS).
April 20, 2024
The artificial heart set to transform medicine – and the Aussie who invented it
Biomedical engineer Daniel Timms lost his father to heart disease. By then, thanks in part to the pair's kitchen-bench experiments, the unassuming Queenslander was well on his way to inventing a permanent, total artificial heart.
April 16, 2024
The world's most advanced long-term artificial heart is on the cusp of implantation
Using magnetic levitation technology, the world's first long-term artificial heart won't wear out, age or break. It's small enough for a child's chest yet robust enough to pump life into an active adult, and it's about to be implanted in human bodies for the very first time.
February 20, 2024
BiVACOR Receives $13 Million to Support Clinical Trials for the Company's Total Artificial Heart
Grant From Monash University's Artificial Heart Frontiers Program, supported by the Australian Government's Medical Research Future Fund, to advance medical technologies for severe heart failure.
January 3, 2024
BiVACOR Names Veteran Medical Device Executive Jim Dillon as Chief Executive Officer
BiVACOR, Inc., a clinical-stage medical technology company developing a total artificial heart (TAH), today announced that Jim Dillon has been named chief executive officer and a member of its board of directors.
December 27, 2023
BiVACOR Appoints Veteran Medical Device Executive Raymond W. Cohen as Chairman of the Board of Directors
BiVACOR, Inc., a clinical-stage medical technology company developing a total artificial heart (TAH), today announced that Raymond W. Cohen has been appointed chairman of its board of directors.
February 16, 2017
The artificial heart that could replace transplants
Daniel Timms spent his childhood learning the mechanics of plumbing from his father. Today he is using that knowledge to create a ground-breaking artificial heart device with the potential to prolong the lives of millions of people with heart failure.
March 4, 2016
Beating the odds – BiVACOR's artificial heart: Daniel Timms' stroke of genius.
A miracle small enough to be implanted inside a child so that they can walk, run, eat, drink, dance and live fully independently without a human heart and without a pulse.
December 5, 2013
Living without a pulse: Engineering a better artificial heart
Scientists at the Texas Heart Institute are working to create a permanent artificial heart. The new heart device propels blood through the body, rather than pumps it. Two magnetic fields control the blades' oscillations, which rotate about 2,000 times a minute.
December 1, 2011
Thirty-one Queensland innovators win $50k each
An artificial heart and a modular bathroom for the mining industry are among the 31 innovations to win up to $50,000 funding as part of a program titled What's your big idea Queensland?
Timms, D.L., Hayne, M., Tan, A.C.C., and Pearcy, M.J., LVAD Pump Performance and Force Characteristics in a Pulsatile Complete Mock Circulation Loop. Artif Organs, 2005. 29(7): p. 572-580. https://pubmed.ncbi.nlm.nih.gov/15982286/
Timms, D., Dunning, J., Thomson, B., Fraser, J., Wilson, K., Dunster, K., McDonald, C., Galbraith, A., and McNeil, K., Acute Animal Experience with the BiVACOR Rotary BiVAD/TAH. Artif Organs, 2008. 32(5): p. A5.
Kaufmann, T.A.S., Hormes, M., Laumen, M., Timms, D.L., Linde, T., Schmitz-Rode, T., Moritz, A., Dzemali, O., and Steinseifer, U., The Impact of Aortic/Subclavian Outflow Cannulation for Cardiopulmonary Bypass and Cardiac Support: A Computational Fluid Dynamics Study. Artif Organs, 2009. 33(9): p. 727-732. PubMed PMID: 19775264 https://pubmed.ncbi.nlm.nih.gov/19775264/
Laumen, M., Kaufmann, T., Timms, D., Schlanstein, P., Jansen, S., Gregory, S., Wong, K.C., Schmitz- Rode, T., and Steinseifer, U., Flow Analysis of Ventricular Assist Device Inflow and Outflow Cannula Positioning Using a Naturally Shaped Ventricle and Aortic Branch. Artif Organs, 2010. 34(10): 798- 806. PubMed PMID: 20964698 https://pubmed.ncbi.nlm.nih.gov/20964698/
Greatrex, N., D. Timms, N. Kurita, E. Palmer, and T. Masuzawa, Axial Magnetic Bearing Development for the BiVACOR Rotary BiVAD/TAH. IEEE Trans. Biomed. Eng., 2010. 57(3): p. 714-721. PubMed PMID: 19822465 https://pubmed.ncbi.nlm.nih.gov/19822465/
Timms, D.L., S.D. Gregory, N.A. Greatrex, M.J. Pearcy, J.F. Fraser, and U. Steinseifer, A Compact Mock Circulation Loop for the In Vitro Testing of Cardiovascular Devices. Artif Organs, 35(4): p. 384-391. PubMed PMID: 20883450 https://pubmed.ncbi.nlm.nih.gov/20883450/
Nestler, F., Bradley, A.P., Wilson, S.J., Timms, D.L., Frazier, O.H., and Cohn, W.E., A Hybrid Mock Circulation Loop for a Total Artificial Heart. Artificial Organs, 2014. 38(9): p. 775-782. PubMed PMID: 25234760 https://pubmed.ncbi.nlm.nih.gov/25234760/
Kleinheyer, M., Timms, D.L., Greatrex, N.A., Masuzawa, T., Frazier, O.H., and Cohn, W.E. Pulsatile operation of the BiVACOR TAH; Motor design, control and hemodynamics. in Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE. 2014. https://ieeexplore.ieee.org/document/6944911
Stevens, M.C., Gregory, S.D., Nestler, F., Thomson, B., Choudhary, J., Garlick, B., Pauls, J.P., Fraser, J.F., and Timms, D., In Vitro and In Vivo Characterization of Three Different Modes of Pump Operation When Using a Left Ventricular Assist Device as a Right Ventricular Assist Device. Artificial Organs, 2014. 38(11): p. 931-939. PubMed PMID: 24660783 https://pubmed.ncbi.nlm.nih.gov/24660783/
Lim, E., Salamonsen, R.F., Mansouri, M., Gaddum, N., Mason, D.G., Timms, D.L., Stevens, M.C., Fraser, J., Akmeliawati, R., and Lovell, N.H., Hemodynamic Response to Exercise and Head‐Up Tilt of Patients Implanted with a Rotary Blood Pump: A Computational Modeling Study. Artificial Organs, 39(2): p. E24-E35. PubMed PMID: 25345482 https://pubmed.ncbi.nlm.nih.gov/25345482/
Gregory, S.D., Stevens, M.C., Pauls, J.P., Schummy, E., Diab, S., Thomson, B., Anderson, B., Tansley, G., Salamonsen, R., Fraser, J.F., and Timms, D., In Vivo Evaluation of Active and Passive Physiological Control Systems for Rotary Left and Right Ventricular Assist Devices. Artificial Organs, 2016 Jan 8. doi: 10.1111/aor.12654. [Epub ahead of print] PubMed PMID: 26748566 https://pubmed.ncbi.nlm.nih.gov/26748566/
Cohn, W.E., Arabia, F., Timms, D.L., Greatrex, N., Kleinheyer, M., Nestler, F., Diab, S., Frazier, O., Pulsatile Outflow in Cows Supported Long-Term with the BiVACOR Rotary TAH. Journal of Heart and Lung Transplantation, Volume 36, Issue 4, Supplement, S14, April 2017. https://www.jhltonline.org/article/S1053-2498(17)30048-7/abstract#%20
Greatrex, N, Kleinheyer, M, Nestler, F, Timms, DL, This Maglev Heart Could Keep Cardiac Patients Alive. IEEE Spectrum, Vol. 9, 22-29, 22 Aug. 2019. https://spectrum.ieee.org/this-maglev-heart-could-keep-cardiac-patients-alive
Timms, D.L., Nestler, F. (2020). BiVACOR Total Artificial Heart. In: Karimov, J., Fukamachi, K., Starling, R. (eds) Mechanical Support for Heart Failure . Springer, Cham. https://doi.org/10.1007/978-3-030-47809-4_35. https://link.springer.com/chapter/10.1007/978-3-030-47809-4_35
Nestler F, Timms DL, Stevens M, Bradley AP, Wilson SJ, Kleinheyer M, Lovell N, Frazier OH, Cohn WE. Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box. Artif Organs. 2020 Jun;44(6):584-593. doi: 10.1111/aor.13631. Epub 2020 Feb 5. PubMed PMID: 31912510. https://pubmed.ncbi.nlm.nih.gov/31912510/
Emmanuel S, Jansz P, McGiffin D, Kure C, Watson A, Connellan M, Granger E, Iyer A, Timms D, Hayward C. Anatomical human fitting of the BiVACOR total artificial heart. Artif Organs. 2022 Jan;46(1):50-56. doi: 10.1111/aor.14077. Epub 2021 Oct 4. PubMed PMID: 34580890. https://pubmed.ncbi.nlm.nih.gov/34580890/
Timms, D.L., Greatrex, N., Nestler, F., Wu, E., Kleinheyer, M., Cohn, W., Frazier, O., Preclinical Evaluation of the Bivacor Total Artificial Heart. The Journal of Heart and Lung Transplantation, Volume 42, Issue 4, Supplement, April 2023, Page S66. https://www.jhltonline.org/article/S1053-2498(23)00185-7/fulltext
Gluck, T., Timms, D.L., Elgalad, A., Shafii, A., Freundt M., Dowling, R., Cohn, W.E. and Frazier, O.H., Pre-Clinical 30-day Survival Results of the BiVACOR TAH. Circulation. 2023;148:A16713. https://www.ahajournals.org/doi/10.1161/circ.148.suppl_1.16713
Kleinheyer, M., Greatrex, N., Nestler, F., Timms, D.L. (2023). BiVACOR Total Artificial Heart and Future Concepts. In: Arabía, F.A. (eds) Mechanical Circulatory Support. Springer, Cham. doi: 10.1007/978-3-030-86172-8_14-1. https://link.springer.com/referenceworkentry/10.1007/978-3-030-86172-8_14-1